Members are currently creating their profile

About the company

Type
Startup or self-employed

Members type
innovator

Headquarters
Global Trade Centre, Wing Kin Rd, Kwai Chung, Hong Kong

Company size
12

Founders
Kar-Wing Lau

Founded
2012

SDG's

  • Affordable and clean energy


Social

Website
allied-control.com

Alliance member

Allied Control Limited


Allied Control offers 2-phase immersion cooling solutions, saving as much as 99% on data center cooling electricity.

Allied Control has built the world's largest 40MW immersion cooled data center with 252kW per single rack resulting in 34.7kW/sqm or 3.2kW/sqft incl. white space, Allied Control offers unparalleled and record-breaking solutions for ultra-high density HPC applications and data centers. Due to its much more efficient cooling technology, it also can provide a very low average pPUE of as low as 1.01 with very hot summer temperatures, combined with very low water usage. This can save as much as 99% on data center cooling electricity, construction materials, etc.

Offer

2-Phase Immersion Cooling Data Centers

Description
2-Phase Immersion Cooling Data Centers can save as much as 99% on cooling electricity and up to 90% of floor space.

Having built the world's largest 40MW immersion cooled data center with 252kW per single rack resulting in 34.7kW/sqm or 3.2kW/sqft incl. white space, Allied Control offers unparalleled and record-breaking solutions for ultra-high density HPC applications. Due to its much more efficient cooling technology, it also can provide a very low average pPUE of as low as 1.01 with very hot summer temperatures, combined with very low water usage. This can save as much as 99% on cooling electricity.

Categories of application
Affordable and clean energy

Sector of application
Energy distribution & management

Status
Implemented


Inbox
Messenger
OPEN DISCUSSION

Make sure you've read the instructions before using the chat
Make sure you've read the instructions before using the chat

Ask your question to the member directly

Every question still pending on the solution should be communicated to the member before rating via this message box. Please, feel free to enquire about more details on specific aspects you judge necessary to assess the criterion below.


Some rules to keep in mind:

  • It’s important for the credibility of the process that your anonymity as an expert is retained. As such, please do not exchange contact details or indicate for whom you are working.
  • Refrain from using the comment box to raise questions on some missing aspects and elements on the solution submission form. Always use the chat box instead.
  • Wait as long as you can for the member to reply before submitting your assessment. If a member is not reacting to a question, please let us know via the “Need Help” tool and we will make a reminder to the solution’s contact.
  • Do not contact members directly to ask for information outside of this online tool (email, skype, phone call).